Dali canteen RO water treatment: site record and sample test information

Site footage and equipment photographs supplied for a canteen project in Dali, with a summary of a 39-item commissioned test report. Its conclusion applies to the submitted sample and tested items described in that report.

Dali canteen RO water treatment: site record and sample test information

Site footage and equipment photographs supplied for a canteen project in Dali, with a summary of a 39-item commissioned test report. Its conclusion applies to the submitted sample and tested items described in that report.

Watch the actual site footage

Visible equipment and project scope

The footage and photographs show a membrane treatment skid, filtration components, a pump, controls and a cylindrical device labelled as ultraviolet disinfection equipment. These identify visible components, rather than establish a particular membrane model, rated output or validated disinfection performance. The project name and location follow the owner’s description.

Commissioned report: source and scope

  • Issuer shown: Dali Bai Autonomous Prefecture Inspection and Testing Institute
  • Report number: SP2026W0357
  • Sample: drinking water; commissioned inspection
  • Received / testing started: 19 January 2026; issued: 9 February 2026

The photographed report states that the tested items of this sample met GB 5749—2022, Standards for drinking water quality. It lists 39 tested items.

Selected values transcribed from the supplied report photographs
ItemReported valueUnit
pH7.2/
Total hardness (as CaCO3)3mg/L
Turbidity<0.5NTU
Total dissolved solids22mg/L
Nitrate (as N)0.1mg/L
Total coliformsNot detected (<2)MPN/100 mL
Escherichia coliNot detected (<2)MPN/100 mL
Colony countNot detected (<1)CFU/mL

How to read these records

This page summarizes four photographs of a submitted-sample report, rather than a new test or an independent authenticity verification. The sampling fields are not completed on the photographed first page; its notes attribute the stated collection location to the commissioning party. The conclusion cannot be extended to untested items, every tap, current operation or continuous water quality. A momentary conductivity display is not interchangeable with laboratory dissolved-solids or microbiological results. Consult the original report and issuing institution when checking applicability.

View actual equipment photographs

Control panel and UV-labelled component

Filter housing, pump and pipework

Conductivity instruments and control cabinet

Canteen handover and maintenance questions

Confirm intended uses, peak service periods, storage turnover, sampling points, cleaning responsibilities and a monitoring plan. Equipment supply, installation, commissioning, sampling, testing and maintenance are distinct responsibilities and should follow the actual agreement.

Official GB 5749—2022 standard information

Field-record directory · Related equipment scope · Discuss your actual requirements